Command: F (Form ZMK). Can be used in online, offline or secure state.
Function: To generate a ZMK component and display it in plain and encrypted forms.
Inputs: None.
Outputs: Clear text ZMK component:
16 or 32 hexadecimal characters.
ZMK component encrypted under a variant of LMK pair 04-05: 16 or 32 hexadecimal
characters.
Component check value; formed by encrypting 64 binary zeros with the component
and returning the left-most 24 bits: 6 hexadecimal characters.
Errors: Internal failure 12: function aborted - the contents of LMK storage have been corrupted or erased. Do not continue. Inform the Security Department.
Example:
Online> F <Return>
Clear ZMK Component: XXXX XXXX XXXX XXXX
Encrypted ZMK Component: XXXX XXXX XXXX XXXX
Key check value: XXXX XXXX XXXX XXXX
Note: You must use 000 not 100 to obtain a valid ZMK from FK command